[1] |
Steffee A,Moore R. Hemi-resurfacing arthroplasty of the shoulder[J] . Contemp Orthop, 1984,9(1): 51-59.
|
[2] |
Copeland S. The continuing development of shoulder replacement: "reaching the surface" [J] . JBJS, 2006,88(4): 900-905.
|
[3] |
Williams GR Jr, Wong KL, Pepe MD, et al. The effect of articular malposition after total shoulder arthroplasty on glenohumeral translations, range of motion, and subacromial impingement[J] . J Shoulder Elbow Surg, 2001,10(5): 399-409.
|
[4] |
Jobe CM,Lannotti JP. Limits imposed on glenohumeral motion by joint geometry[J] . J Shoulder Elbow Surg, 1995,4(4): 281-285.
|
[5] |
Büchler P,Farron A. Benefits of an anatomical reconstruction of the humeral head during shoulder arthroplasty: a finite element analysis[J] . Clin Biomech, 2004,9(1): 16-23.
|
[6] |
Phillips J, Runciman R,Miniaci A. Mathematical modeling of humeral head geometry[J]. Shoulder Elbow Surg,2004,24(3): 213-218.
|
[7] |
Kennon JC, Smith JP,Crosby LA. Core decompression and arthroplasty outcomes for atraumatic osteonecrosis of the humeral head[J] . J Shoulder Elbow Surg, 2016,25(9): 1442-1448.
|
[8] |
Hammond G, Tibone JE, McGarry MH, et al. Biomechanical comparison of anatomic humeral head resurfacing and hemiarthroplasty in functional glenohumeral positions[J] . J Bone Joint Surg Am, 2012,94(1): 68-76.
|
[9] |
Bixby EC, Sonnenfeld JJ, Alrabaa RG, et al. Partial Humeral Head Resurfacing for Avascular Necrosis[J] . Arthrosc Tech, 2020,9(1): 185-189.
|
[10] |
Sweet SJ, Takara T, Ho L, et al. Primary partial humeral head resurfacing: outcomes with the HemiCAP implant[J] . Am J Sports Med, 2015,43(3): 579-587.
|
[11] |
Anderl W, Kriegleder B, Neumaier M, et al. Arthroscopic partial shoulder resurfacing[J] . Knee Surg Sports Traumatol Arthrosc, 2015,23(5): 1563-1570.
|
[12] |
Ranalletta M, Bertona A, Tanoira I, et al. Results of partial resurfacing of humeral head in patients with avascular necrosis[J]. Rev Esp Cir Ortop Traumatol (Engl Ed), 2019,63(1): 29-34.
|
[13] |
Holschen M, Berg D, Schulte T, et al. Arthroscopic and open partial arthroplasty for the treatment of focal grade IV cartilage defects of the humeral head[J] . Arch Orthop Trauma Surg, 2021,141(9): 1455-1462.
|
[14] |
Gill DR, Graves SE, Rainbird S, et al. A comparison of revision rates for osteoarthritis of primary reverse total shoulder arthroplasty to primary anatomic shoulder arthroplasty with a cemented all-polyethylene glenoid: analysis from the Australian Orthopaedic Association National Joint Replacement Registry[J] . Clin Orthop Relat Res, 2021,479(10): 2216-2224.
|
[15] |
Giles JW, Elkinson I, Ferreira LM, et al. Moderate to large engaging Hill-Sachs defects: an in vitro biomechanical comparison of the remplissage procedure, allograft humeral head reconstruction, and partial resurfacing arthroplasty[J] . J Shoulder Elbow Surg, 2012, 21(9): 1142-1151.
|
[16] |
Pape G, Zeifang F, Bruckner T, et al. Humeral surface replacement for the sequelae of fractures of the proximal humerus[J] . J Bone Joint Surg(British),2010,92(10): 1403-1409.
|
[17] |
Amri K, Chefi MA, Znagui T, et al. Resurfacing shoulder hemi arthroplasty in ballistic injuries. a case report[J] . Int J Surg Case Rep, 2019,65(1): 48-51.
|
[18] |
Rai P, Davies O, Wand J, et al. Long-term follow-up of the Copeland mark III shoulder resurfacing hemi-arthroplasty[J] . J Orthop, 2016,13(1): 52-56.
|
[19] |
Dekker AP, Joshi N, Morgan M, et al. 6-Year clinical results and survival of Copeland Resurfacing hemiarthroplasty of the shoulder in a consecutive series of 279 cases[J] . J Clin Orthop Trauma, 2020,11(Suppl 2): 265-269.
|
[20] |
Bülhoffa M, Sowa B, Bruckner T, et al. Getting back in the game after humeral head resurfacing[J] . J Orthop, 2018,15(1): 264-274.
|
[21] |
Soudy K, Szymanski C, Lalanne C, et al. Results and limitations of humeral head resurfacing: 105 cases at a mean follow-up of 5 years[J] . Orthop Traumatol Surg Res, 2017,103(3): 415-420.
|
[22] |
Werner BS, Stehle J, Abdelkawi A, et al. Progressive glenoid bone loss caused by erosion in humeral head resurfacing[J] . Orthopade, 2017,46(12): 1028-1033.
|
[23] |
Levy O, Tsvieli O, Merchant J, et al. Surface replacement arthroplasty for glenohumeral arthropathy in patients aged younger than fifty years: results after a minimum ten-year follow-up[J] . J Shoulder Elbow Surg, 2015,24(7): 1049-1060.
|
[24] |
Glanzmann MC, Kolling C, Schwyzer HK, et al. Radiological and functional 24-month outcomes of resurfacing versus stemmed anatomic total shoulder arthroplasty[J] . Int Orthop, 2017,41(2): 375-384.
|
[25] |
Levy O,Copeland S. Cementless surface replacement arthroplasty of the shoulder: 5-to 10-year results with the Copeland mark-2 prosthesis[J] . J Bone Joint Surg(British ), 2001,83(2): 213-221.
|
[26] |
Copeland S. The continuing development of shoulder replacement: "reaching the surface" [J] . J Bone Joint Surg Am, 2006,88(4): 900-905.
|
[27] |
Mechlenburg I, Klebe TM, Dossing KV, et al. Evaluation of periprosthetic bone mineral density and postoperative migration of humeral head resurfacing implants: two-year results of a randomized controlled clinical trial[J] . J Shoulder Elbow Surg, 2014,23(10): 1427-1436.
|
[28] |
Schmidutz F, Sprecher CM, Milz S, et al. Resurfacing of the humeral head: An analysis of the bone stock and osseous integration under the implant[J] . J Orthop Res, 2015,33(9): 1382-1390.
|
[29] |
Burgess DL, McGrath MS, Bonutti PM, et al. Shoulder resurfacing[J] . J Bone Joint Surg Am, 2009,91(5): 1228-1238.
|
[30] |
Bellamy JL, Johnson AE, Beltran MJ, et al. Quantification of the exposure of the glenohumeral joint from the minimally invasive to more invasive subscapularis approach to the anterior shoulder: a cadaveric study[J] . J Shoulder Elbow Surg, 2014, 23(6): 895-901.
|
[31] |
Chong PY, Srikumaran U, Kuye IO, et al. Glenohumeral arthritis in the young patient[J] . J Shoulder Elbow Surg, 2011,20(2 Suppl): 30-40.
|
[32] |
Saltzman BM, Leroux TS, Verma NN, et al. Glenohumeral Osteoarthritis in the Young Patient[J] . J Am Acad Orthop Surg, 2018,26(17): 361-370.
|
[33] |
Elhassan B, Ozbaydar M, Diller D, et al. Soft-tissue resurfacing of the glenoid in the treatment of glenohumeral arthritis in active patients less than fifty years old[J] . JBJS, 2009,91(2): 419-424.
|
[34] |
Muh SJ, Streit JJ, Shishani Y, et al. Biologic resurfacing of the glenoid with humeral head resurfacing for glenohumeral arthritis in the young patient[J] . J Shoulder Elbow Surg, 2014,23(8): 185-190.
|
[35] |
Raiss P, Weiter M, Sowa B, et al. Results of cementless humeral head resurfacing with cemented glenoid components[J] . Int Orthop, 2015,39(2): 277-284.
|
[36] |
Fourman MS, Beck A, Gasbarro G, et al. Humeral head resurfacing is associated with less pain and clinically equivalent functional outcomes compared with stemmed hemiarthroplasty at mid-term follow-up[J] . Knee Surg Sports Traumatol Arthrosc, 2019,27(10): 3203-3211.
|
[37] |
Thangarajah T, Ajami S, Coathup M, et al. Revision shoulder arthroplasty for failed humeral head resurfacing hemiarthroplasty[J]. Shoulder Elbow, 2019,11(2 Suppl): s35-41.
|
[38] |
Maier MW, Hetto P, Raiss P, et al. Cementless humeral head resurfacing for degenerative glenohumeral osteoarthritis fails at a high rate[J] . J Orthop, 2018,15(2): 349-353.
|
[39] |
Verstraelen FU, Horta LA, Schotanus MGM, et al. Clinical and radiological results 7 years after Copeland shoulder resurfacing arthroplasty in patients with primary glenohumeral osteoarthritis: an independent multicentre retrospective study[J] . Eur J Orthop Surg Traumatol, 2018,28(1): 15-22.
|
[40] |
Williams GR. Arthritis and arthroplasty: the shoulder[M] . America,Elsevier Health Sciences,2009:239-242.
|
[41] |
Jacobson JA, Girish G, Jiang Y, et al. Radiographic evaluation of arthritis: inflammatory conditions[J] . Radiology, 2008,248(2): 378-389.
|
[42] |
Walch G, Badet R, Boulahia A, et al. Morphologic study of the glenoid in primary glenohumeral osteoarthritis[J] . J Arthroplasty, 1999,14(6): 756-760.
|
[43] |
Armitage MS, Faber KJ, Drosdowech DS, et al. Humeral head bone defects: remplissage, allograft, and arthroplasty[J] . Orthop Clin North Am, 2010,41(3): 417-425.
|
[44] |
Denard PJ,Walch G. Current concepts in the surgical management of primary glenohumeral arthritis with a biconcave glenoid[J] . J Shoulder Elbow Surg, 2013, 22(11): 1589-1598.
|
[45] |
Mori D, Abboud JA, Namdari S, et al. Glenoid bone loss in anatomic shoulder arthroplasty: literature review and surgical technique[J] . Orthop Clin North Am, 2015,46(3): 389-397.
|
[46] |
Youderian AR, Napolitano LA Jr, Davidson IU, et al. Management of glenoid bone loss with the use of a new augmented all-polyethylene glenoid component[J] . Tech Shoulder Elbow Surg, 2012,13(4): 163-169.
|
[47] |
McBride AP, Ross M, Hoy G, et al. Mid-term outcomes of pyrolytic carbon humeral resurfacing hemiarthroplasty compared with metal humeral resurfacing and metal stemmed hemiarthroplasty for osteoarthritis in young patients: analysis from the australian orthopaedic association national joint replacement registry[J] . J Shoulder Elbow Surg, 2021, 31(4): 755-762.
|
[48] |
Yalcin S, Scarcella M, Everhart J, et al. Clinical and radiographic outcomes of total shoulder arthroplasty with a nonspherical humeral head and inlay glenoid in elite weight lifters: a prospective case series[J] . Orthop J Sports Med, 2021,9(7): 23-25.
|
[49] |
Egger AC, Peterson J, Jones MH, et al. Total shoulder arthroplasty with nonspherical humeral head and inlay glenoid replacement: clinical results comparing concentric and nonconcentric glenoid stages in primary shoulder arthritis[J] . JSES Open Access, 2019, 3(3): 145-153.
|
[50] |
Uribe JW, Zvijac JE, Porter DA, et al. Inlay total shoulder arthroplasty for primary glenohumeral arthritis[J] . JSES Int, 2021, 5(6): 1014-1020.
|
[51] |
Al-Hadithy N, Domos P, Sewell MD, et al. Cementless surface replacement arthroplasty of the shoulder for osteoarthritis: results of fifty Mark III copeland prosthesis from an independent center with four-year mean follow-up[J] . J Shoulder Elbow Surg, 2012, 21(12): 1776-1781.
|
[52] |
Geervliet PC, Willems JH, Sierevelt IN, et al. Overstuffing in resurfacing hemiarthroplasty is a potential risk for failure[J] . J Orthop Surg Res, 2019,14(1): 474.
|
[53] |
Mechlenburg I, Amstrup A, Klebe T, et al. The Copeland resurfacing humeral head implant does not restore humeral head anatomy. a retrospective study[J] . Arch Orthop Trauma Surg, 2013,133(5): 615-619.
|
[54] |
Moor B, Bouaicha S, Rothenfluh D, et al. Is there an association between the individual anatomy of the scapula and the development of rotator cuff tears or osteoarthritis of the glenohumeral joint? A radiological study of the critical shoulder angle[J] . Bone Joint J, 2013,95(7): 935-941.
|
[55] |
Viehöfer AF, Gerber C, Favre P, et al. A larger critical shoulder angle requires more rotator cuff activity to preserve joint stability[J]. J Orthop Res, 2016,34(6): 961-968.
|
[56] |
von Engelhardt LV, Hahn M, Schulz T, et al. Changes of the bone structure after cap resurfacing arthroplasty of the humeral head[J]. Orthop Traumatol Surg Res, 2017, 103(4): 493-498.
|
[57] |
Rasmussen JV, Olsen BS, Al-Hamdani A, et al. Outcome of Revision Shoulder Arthroplasty After Resurfacing Hemiarthroplasty in Patients with Glenohumeral Osteoarthritis[J] . J Bone Joint Surg Am, 2016, 98(19): 1631-1637.
|
[58] |
Gaeremynck P, Amouyel T, Saab M, et al. Clinical and radiological outcomes of 17 reverse shoulder arthroplasty cases performed after failed humeral head resurfacing[J] . Orthop Traumatol Surg Res, 2019,105(8): 1495-1501.
|
[59] |
Jonas SC, Walton MJ,Sarangi PP. Management of a periprosthetic fracture after humeral head resurfacing total shoulder replacement: a case report[J] . J Shoulder Elbow Surg, 2011,20(5): 18-21.
|